4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
主营:原厂直采,平行进口,授权代理(蚂蚁淘为您服务)
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > sequencing_reagents > 生物测定系统/EnzyChrom™肌酐测定试剂盒/100试验/EICT-100
商品详细生物测定系统/EnzyChrom™肌酐测定试剂盒/100试验/EICT-100
生物测定系统/EnzyChrom™肌酐测定试剂盒/100试验/EICT-100
生物测定系统/EnzyChrom™肌酐测定试剂盒/100试验/EICT-100
商品编号: EICT-100
品牌: bioassaysys
市场价: ¥6780.00
美元价: 3390.00
产地: 美国(厂家直采)
公司:
产品分类: 簇生成和测序试剂
公司分类: sequencing_reagents
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍

EnzyChrom™ Creatinine Assay Kit

EnzyChrom™ Creatinine Assay Kit Catalog No: EICT-100
Price: $339 Qty:
For orders of 10 or more kits, please call +1-510-782-9988x1 oremail us for best pricing and/or bulk order. Shipping: On Ice Shipment: Fedex ServiceDelivery: 1-2 days (US), 3-6 days (Intl) Storage: -20°C
Creatinine Assay Kit (EICT-100)
  • Product Overview
  • Product FAQ
  • Product Citations
  • Assay Service
ProtocolSDS

Application

  • Creatinine determination in urine, serum, plasma, and other biological preparations.

Key Features

  • Fast and sensitive. Linear detection range: 10.6 to 500 µM or 0.12-5.7 mg/dL (colorimetric assay) and 0.25 to 50 µM or 0.0028-0.57 mg/dL (fluorimetric assay) for a 60 min reaction.
  • Convenient. The procedure involves adding a single working reagent and reading after 60 minutes.
  • High-throughput. Homogeneous "mix-incubate-measure" type assay. Can be readily automated to process thousands of samples per day.

Method

  • OD570nm; FL530/585nm

Samples

  • Urine, serum, plasma, and other biological preparations.

Species

  • All

Size

  • 100 tests

Detection Limit

  • Colorimetric assay: 10.6 µM or 0.12 mg/dL; Fluorimetric assay: 0.25 µM or 0.0028 mg/dL

Shelf Life

  • 6 months

More Details

  • CREATININE is synthesized in the body from creatine, which is produced during muscle contractions from creatine phosphate. In the blood, creatinine is removed by filtration through the glomeruli of the kidney and is secreted into urine. In healthy individuals, creatinine secretion is independent of diet and is fairly constant. The creatinine clearance test has become one of the most sensitive tests for measuring glomerular filtration rate. In kidney disease, creatinine levels in the blood are elevated, whereas the creatinine clearance rate and hence the urine levels are diminished. Creatinine testing is most widely used to assess kidney function.BioAssay Systems’ enzyme-based creatinine assay uses a reaction sequence that excludes both endogenous creatine and ammonia to convert a dye into a colored and fluorescent form. The absorbance at 570 nm or fluorescence intensity at λex/em = 530/585 nm is directly proportional to the creatinine concentration in the sample.

What samples have you tested?

This kit has been tested and validated in urine, plasma, and serum samples.

Can I store unused reagents for future use?

Yes, unused reagents can be stored according to the assay protocol.

How do you use this kit on deproteinated plasma or serum samples with an internal standard procedure?

Samples will need three separate reactions: 1) sample plus standard2) sample alone 3) sample blank. For the internal standard prepare 200 µL 1250 µM standard by mixing 125 µL 2 mM Standard and 75 µL dH2O. For the sample plus standard well, add 5 µL 1250 µM standard and 20 µL sample. For the sample and sample blank wells, add 5 µL dH2O and 20 µL sample. Prepare enough Working Reagent (WR) for all assay wells by mixing, for each well, 80 µL Assay Buffer, 1 µL Enzyme A, 1 µL Enzyme Mix, 1 µL ATP, 1 µL Dye Reagent. Prepare a WR without the Enzyme A for the sample blank well(s). Add 80 µL of the WR to each well. Tap plate briefly to mix. Incubate at room temperature for 60 min. Use a plate reader to read OD570nm. The sample creatinine concentration is computed as follows: [Creatinine] = (RSAMPLE – RBLANK)/(RSTANDARD – RSAMPLE) x [Standard]/4 x n(µM)where RSAMPLE, RBLANK, and RSTANDARD are the OD or fluorescence values of the Sample, Sample Blank, and the Sample plus Standard respectively. n is the sample dilution factor. Note: The volume of the internal standard is 4× lower than the sample volume; thus, the internal standard concentration should be divided by 4.For more detailed product information and questions, please feel free to Contact Us. Or for more general information regarding our assays, please refer to our General Questions.
No citations for this new product. Please check back later.You mayclick here to check if citations are available, but are not listed here yet.
If you or your labs do not have the equipment or scientists necessary to run this assay, BioAssay Systems can perform the service for you.Simply send us your samples:- Fast turnaround - Quality data - Low costPlease email or call 1-510-782-9988 x 2 to request assay service.
品牌介绍
BioAssay Systems位于加州北部,是一家专注于提供高质量试剂盒的生物技术公司,试剂盒种类广泛、使用简便、操作简单、快速且性能优越,用户不需花额外的时间来作调适测试。BioAssay Systems产品具有快速、简单、高通量(可用于HTS药物筛选)、灵敏(特别适合小鼠样品) 、准确性高和低干扰等主要特征,且采用发光、生物发光、化学发光、荧光等非放射性的检测技术,安全无害可靠。